OHE Maintenance Hot line tools

Showing 1 – 168 of 168 results Showing all 168 results Showing the single result No results found
Category
Sort by Name A - Z
Showing 1 – 168 of 168 results Showing all 168 results Showing the single result No results found
Filters Sort results
Reset Apply
Syselec Product ID
Product Image
Item Name / Catalogue Description
Product Category
Dimensions / Size
Application
Add to cart
SYS-TEC-TM02120140-01
Adjustable insulator forks
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Supports, guides, or positions insulators during installation and maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03150201-01
Adjustable Pole Clamp
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Secures temporary support equipment to a pole or insulated pole during line work.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070605-01
All-angle grounding clamp (with large jaw)
Temporary Grounding Equipment and Hot Sticks

Connection range Ø 6.5-73 mm; cable terminal range 16-95 mm².

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120107-01
All-angle pliers
Insulated Hand Tools

Physical dimensions are not stated in the provided datasheet.

Grips and manipulates small line components at different approach angles using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM10030101-01
Assistance pulley bracket
Compact Networks

To be designed as per IEC, ASTM codes

Supports a pulley used to guide conductor or cable during compact-network installation.
Max:
Min: 1
Step: 1
SYS-TEC-TM03080105-01
Auxiliary arm assembly
Conductor Support Equipment

Auxiliary-arm stick Ø 64 × 1780 mm insulated length; mast pole Ø 64 × 1360 mm insulated length.

Provides temporary multi-point support for conductors when the normal crossarm arrangement is disturbed.
Max:
Min: 1
Step: 1
SYS-TEC-TM03080101-01
Auxiliary crossarm
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Provides temporary multi-point support for conductors when the normal crossarm arrangement is disturbed.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120104-01
Ball socket adjuster, long
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Aligns and manipulates ball-and-socket insulator hardware during assembly or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120130-01
Ball socket adjuster, short
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Aligns and manipulates ball-and-socket insulator hardware during assembly or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070104-01
Ball socket grounding clamp
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM09040101-01
Bare-hand stick
Bare-hand Equipment

Rod Ø 32 mm (1-1/4 in); insulating length 340 mm (1 ft 4 in); connection range Ø 12-48 mm.

Supports bare-hand or equipotential live-line work by allowing controlled handling at conductor potential.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070403-01
Bus-bar grounding clamp
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070401-01
C-type grounding clamp for substation
Temporary Grounding Equipment and Hot Sticks

Connection range: minimum Ø 5 mm; maximum Ø 50 mm or rectangular bars 12 × 100 mm.

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070302-01
C-type grounding clamp, T-handle
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM03080104-01
C-type wire holder, no insulator
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Temporarily holds and positions a conductor during live-line construction or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM01120101-01
Cable wire rope grip puller
Load Handling Equipment

Cable diameter range: Ø 5.08-10.16 mm (0.20-0.40 in).

Grips and tensions conductor, guy wire, or wire rope during line construction, sagging, or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM13060101-01
Canvas bag for insulated gloves
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13060201-01
Canvas bag for insulated gloves and sleeves
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13010201-01
Canvas bucket No. 8, canvas bottom
Tool Bags

Size designation: No. 8; physical dimensions not specified

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13050101-01
Canvas hot stick bag, for sectional hot stick
Tool Bags

To be designed as per IEC, ASTM codes

Provides modular insulated reach for operating line hardware or applying grounding equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13050201-01
Canvas hot stick storage bag
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13020201-01
Canvas storage bag for three-phase grounding set
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13040201-01
Canvas tool bag (lockable)
Tool Bags

length 500 mm × height 330 mm × width 190 mm.

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13010101-01
Canvas tool bucket
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13040301-02
Canvas tool pouch with shoulder strap, without lid
Tool Bags

Syselec ID uniquely identifies this pictured variant.

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13040301-01
Canvas tool pouch, with lid and shoulder strap
Tool Bags

Height 350 mm × width 300 mm × thickness 80 mm; shoulder strap length 1000 mm.

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120116-01
Chuck blank
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Serves as a universal tool holder for attaching a suitable custom or interchangeable hot-stick tool.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120129-01
Clamp stick head
Insulated Hand Tools

Clamp capacity up to 152 mm

Engages and operates compatible clamps from a hot stick while maintaining working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12170101-01
Clamp stick head, locking system by adjustable pressure half-ball
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Engages and operates compatible clamps from a hot stick while maintaining working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120133-01
Clear vision mirror
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Provides remote visual inspection of hidden or obstructed components near energized equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050301-01
Clevis device for auxiliary crossarm
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Connects and supports an auxiliary crossarm assembly during temporary conductor support work.
Max:
Min: 1
Step: 1
SYS-TEC-TM01160101-01
Coil catcher
Load Handling Equipment

To be designed as per IEC, ASTM codes

Captures and controls a coil or loose conductor during handling to reduce uncontrolled movement.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120155-01
Conductor cleaning brush
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Cleans conductor surfaces before installing clamps, jumpers, connectors, or other line hardware.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120168-01
Conductor cleaning brush, V position
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Cleans conductor surfaces before installing clamps, jumpers, connectors, or other line hardware.
Max:
Min: 1
Step: 1
SYS-TEC-TM07070301-01
Conductor cover
Insulating Cover-up Equipment

Length 1560 mm (5 ft 1 in); suitable conductor diameter up to 25 mm.

Temporarily covers an energized conductor to reduce accidental contact and phase-to-ground exposure.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120122-01
Cotter key holder
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs, holds, or removes cotter keys and retaining pins from line hardware using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120158-01
Cotter key puller
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs, holds, or removes cotter keys and retaining pins from line hardware using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM03280704-01
Cradle spacer
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Maintains spacing and separation within a temporary conductor-support or cradle arrangement.
Max:
Min: 1
Step: 1
SYS-TEC-TM03070207-01
Cross arm clamp
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Secures an auxiliary crossarm or support assembly to a pole or structure.
Max:
Min: 1
Step: 1
SYS-TEC-TM03110101-01
Crossarm conductor support
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Temporarily supports a conductor at crossarm level during maintenance or component replacement.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120113-01
Cutout tool
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Operates fuse cutouts or fuse switches from an insulated distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080106-01
Diagonal crosspiece
Insulated Scaffold and Ladders

Diagonal scaffold crosspiece length: 1410 mm.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM01090108-01
Double rope block
Load Handling Equipment

Width 80 mm (3-1/8 in); length 300 mm (11-3/4 in).

Provides mechanical advantage for lifting, lowering, or positioning tools and components using rope.
Max:
Min: 1
Step: 1
SYS-TEC-TM06040201-01
Double stringer extension ladder
Insulated Scaffold and Ladders

To be designed as per IEC, ASTM codes

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06090201-01
Extension ladder with oblong profile and fiberglass steps
Insulated Scaffold and Ladders

Profile P70; closed length 3.45 m (11 ft 2 in); open length 5.86 m (18 ft 4 in); 19 steps.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06120111-01
Fiberglass mobile platform ladder
Insulated Scaffold and Ladders

To be designed as per IEC, ASTM codes

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070702-01
Flat-face grounding clamp
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070701-01
Flat-face grounding clamp (bench vice type)
Temporary Grounding Equipment and Hot Sticks

Connection range 3.2-38 mm for rectangular bars; cable terminal range 16-95 mm².

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120136-01
Flexible wrench head
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Operates fasteners or hardware from a universal hot stick during energized or restricted-access maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03070201-01
Fork type wire holder
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Temporarily holds and positions a conductor during live-line construction or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120145-01
Fuse puller
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Removes or installs fuse holders and related components from an insulated distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM08120101-01
Glove tester
Instruments and Meters

To be designed as per IEC, ASTM codes

Inflates insulating gloves so the user can check for air leaks, punctures, or visible damage before use.
Max:
Min: 1
Step: 1
SYS-TEC-TM02020101-01
Grip-all clampstick (Shotgun stick)
Insulated Hand Tools

Datasheet variant TM02020106: rod Ø 32 mm (1-1/4 in); insulating length 540 mm; total length 1430 mm.

Operates clamps, switches, and line hardware from an insulated working distance during live-line maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12100102-01
Ground clamp cluster
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Groups grounding clamp connections for organized temporary grounding arrangements.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070705-01
Ground clamp for connection to ground point (mobile jaw)
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Connects a temporary grounding cable to a designated ground point using a mobile-jaw clamp.
Max:
Min: 1
Step: 1
SYS-TEC-TM12110101-01
Ground cluster bar
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Creates an equipotential connection point for multiple temporary grounding leads.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120125-01
Hack saw
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Provides remote sawing of suitable components using a universal hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120151-01
Hammer with universal adapter
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Connects a specialized attachment to a universal hot stick for remote electrical maintenance work.
Max:
Min: 1
Step: 1
SYS-TEC-TM01100101-01
Hand line block with forged steel hook
Load Handling Equipment

suitable for rope up to Ø 5/8 in (15.9 mm).

Used with a hand line to lift, lower, or position tools and materials on poles or structures.
Max:
Min: 1
Step: 1
SYS-TEC-TM01100103-01
Hand line block with meat hook
Load Handling Equipment

suitable for rope up to Ø 1/2 in (12.7 mm).

Used with a hand line to lift, lower, or position tools and materials on poles or structures.
Max:
Min: 1
Step: 1
SYS-TEC-TM01100201-01
Hand line hook
Load Handling Equipment

To be designed as per IEC, ASTM codes

Provides an attachment point for hand lines when lifting or controlling tools and materials.
Max:
Min: 1
Step: 1
SYS-TEC-TM12170302-01
Head for operation of fuse switches
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Operates fuse cutouts or fuse switches from an insulated distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02020201-01
Hinged grip-all clampstick (Hinged shotgun stick)
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Operates clamps, switches, and line hardware from an insulated working distance during live-line maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120174-01
Hot line applicator
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Applies or positions hot-line accessories and fittings from an insulated working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120117-01
Hot rodder tool
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs or removes preformed conductor ties and similar line fittings using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120117-02
Hot rodder tool
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs or removes preformed conductor ties and similar line fittings using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM13050301-01
Hot stick bag, for single hot stick
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM14030201-01
HV crossarm pulley
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Guides cable or conductor during pulling, paying-out, or installation on the stated network structure.
Max:
Min: 1
Step: 1
SYS-TEC-TM10030102-01
Input pulley bracket
Compact Networks

To be designed as per IEC, ASTM codes

Supports a pulley used to guide conductor or cable during compact-network installation.
Max:
Min: 1
Step: 1
SYS-TEC-TM02190103-01
Insulated adjustable wrench
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Tightens or loosens fasteners near energized parts while providing an insulated handle.
Max:
Min: 1
Step: 1
SYS-TEC-TM02130101-01
Insulated bolt cutter
Insulated Hand Tools

Size 24 in; handle/rod Ø 32 mm (1-1/4 in); insulating length 350 mm (13-3/4 in); cutting capacity Ø 11.11 mm (7/16 in).

Cuts bolts, wire, or conductor-related hardware while providing insulation between the user and the work area.
Max:
Min: 1
Step: 1
SYS-TEC-TM02190101-01
Insulated Fix Wrench
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Tightens or loosens fasteners near energized parts while providing an insulated handle.
Max:
Min: 1
Step: 1
SYS-TEC-TM05110101-01
Insulated hanger
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Supports and positions insulated temporary jumpers to control clearance and mechanical loading.
Max:
Min: 1
Step: 1
SYS-TEC-TM02130301-01
Insulated lever type wire cutter
Insulated Hand Tools

Rod Ø 32 mm (1.26 in); insulating length 1160 mm (45.67 in); cutting capacity Ø 10.11 mm (0.40 in).

Cuts bolts, wire, or conductor-related hardware while providing insulation between the user and the work area.
Max:
Min: 1
Step: 1
SYS-TEC-TM06-ASSY-01
Insulated modular scaffolding assembly (catalogue illustration)
Insulated Scaffold and Ladders

Configuration-dependent; assembled from modular scaffold components

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02190102-01
Insulated Socket Wrench
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Tightens or loosens fasteners near energized parts while providing an insulated handle.
Max:
Min: 1
Step: 1
SYS-TEC-TM06070101-01
Insulated stool
Insulated Scaffold and Ladders

To be designed as per IEC, ASTM codes

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02060101-01
Insulating grip pole for pliers
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Allows plier-type operations to be performed from an insulated distance near energized equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM05050201-01
Jumper set for hotstick applications, with snap-on (duckbill-type) clamp
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Provides a temporary insulated electrical bypass so service continuity can be maintained during maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120123-01
Locating pin
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Aligns holes and positions pins in line hardware during assembly or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM14030301-01
LV cable release pulley, rack fitting
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Guides cable or conductor during pulling, paying-out, or installation on the stated network structure.
Max:
Min: 1
Step: 1
SYS-TEC-TM01110201-01
Nylon webbing sling
Load Handling Equipment

To be designed as per IEC, ASTM codes

Wraps and supports equipment or components for lifting and handling without direct metal-to-surface contact.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120112-01
Pin holder
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Holds pins or small line hardware during installation, removal, or alignment from a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM14040101-01
Pole belt
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Assists a lineworker in climbing or positioning on a utility pole under an approved work-at-height procedure.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050208-01
Pole clamp
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Secures temporary support equipment to a pole or insulated pole during line work.
Max:
Min: 1
Step: 1
SYS-TEC-TM07010304-01
Pole cover
Insulating Cover-up Equipment

To be designed as per IEC, ASTM codes

Temporarily covers a pole or adjacent surface to reduce accidental contact during live-line work.
Max:
Min: 1
Step: 1
SYS-TEC-TM02010101-01
Pole wrench
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Provides leverage for turning, aligning, or handling utility poles during installation and maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120126-01
Pruning saw
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Trims vegetation near overhead conductors while maintaining increased working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM14030401-01
Pulley for cable release in transmission lines
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Guides cable or conductor during pulling, paying-out, or installation on the stated network structure.
Max:
Min: 1
Step: 1
SYS-TEC-TM14030101-01
Pulley for multiplex cable release
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Guides cable or conductor during pulling, paying-out, or installation on the stated network structure.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080118-01
Rails for scaffolding
Insulated Scaffold and Ladders

Three pairs of 2 m tracks; total track length 6 m; for a 1.0 × 1.0 m base scaffold.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03200114-01
Ratchet wrench
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Tightens or adjusts conductor-support hardware and related assemblies.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120114-01
Ratchet wrench with universal fitting
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Operates fasteners or hardware from a universal hot stick during energized or restricted-access maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03140101-01
Roller link stick
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Supports or guides mechanical line loads through a roller-linked insulated stick during conductor work.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050101-01
Rope snubbing bracket
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Anchors or controls a rope to prevent uncontrolled movement during lifting and line handling.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120142-01
Rotary blade tie stick head
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs, adjusts, or removes conductor ties using rotational hot-stick action.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120141-01
Rotary prong tie stick head
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs, adjusts, or removes conductor ties using rotational hot-stick action.
Max:
Min: 1
Step: 1
SYS-TEC-TM07130101-01
Rubber blanket clamp
Insulating Cover-up Equipment

Width 75 mm (3 in); length 210 mm (8-1/4 in); maximum opening 80 mm (3-1/8 in).

Secures an insulating rubber blanket around energized parts or grounded structures.
Max:
Min: 1
Step: 1
SYS-TEC-TM05050101-01
Rubber glove jumper set
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Provides a temporary insulated electrical bypass so service continuity can be maintained during maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12040102-01
Running travelling ground
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Maintains a moving grounding contact on a conductor during stringing, pulling, or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080115-01
Scaffolding leveling jack with caster
Insulated Scaffold and Ladders

Configured for a 1.0 × 1.0 m scaffold base; supplied as stabilizer feet with casters.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080301-01
Scaffolding module, 0.5 x 1.0 m
Insulated Scaffold and Ladders

Scaffold module: 0.5 × 1.0 m.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080101-01
Scaffolding module, 1.0 x 1.0 m
Insulated Scaffold and Ladders

Scaffold module: 1.0 × 1.0 m.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080102-01
Scaffolding module, 2.0 x 1.0 m
Insulated Scaffold and Ladders

Scaffold module: 2.0 × 1.0 m.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080109-01
Scaffolding platform
Insulated Scaffold and Ladders

Scaffolding platform: 2.0 × 1.0 m (four 1.0 × 0.5 m planks).

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12120601-01
Screw ground rod
Temporary Grounding Equipment and Hot Sticks

Stem Ø 17 mm (5/8 in); total length 1500 mm (4 ft 11 in).

Provides a temporary earth electrode for grounding equipment in suitable soil.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120128-01
Screwdriver with universal fitting
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Operates fasteners or hardware from a universal hot stick during energized or restricted-access maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM07080101-01
Secondary conductor cover (LV)
Insulating Cover-up Equipment

To be designed as per IEC, ASTM codes

Temporarily covers an energized conductor to reduce accidental contact and phase-to-ground exposure.
Max:
Min: 1
Step: 1
SYS-TEC-TM12160205-01
Sectional hot stick
Temporary Grounding Equipment and Hot Sticks

Three-section set; total length 3950 mm (13 ft); tip Ø 32 mm; intermediate and handle sections Ø 38 mm.

Provides modular insulated reach for operating line hardware or applying grounding equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120134-01
Shepherd hook
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Hooks, pulls, or positions conductors and line hardware from an insulated distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM12020102-01
Short circuit stick with 4 clamps for bare vertical secondary overhead systems
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Applies temporary short-circuiting and grounding connections to bare low-voltage secondary systems.
Max:
Min: 1
Step: 1
SYS-TEC-TM12020101-01
Short circuit stick with 5 clamps for bare vertical secondary overhead systems
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Applies temporary short-circuiting and grounding connections to bare low-voltage secondary systems.
Max:
Min: 1
Step: 1
SYS-TEC-TM06080105-01
Side crosspiece
Insulated Scaffold and Ladders

Side scaffold crosspiece length: 2000 mm.

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM14010101-01
Signaling tape reel
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Deploys and retrieves barricade or warning tape around a controlled work area.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050112-01
Single type lever lift wire tong support
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Raises and supports a wire tong using a lever mechanism during conductor repositioning.
Max:
Min: 1
Step: 1
SYS-TEC-TM12070301-01
Snap-on (duckbill-type) grounding clamp
Temporary Grounding Equipment and Hot Sticks

Main-line connection range Ø 4-29 mm; jumper/cable terminal range 16-95 mm².

Connects a temporary grounding cable to the stated conductor, busbar, bushing, or ground point.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120120-01
Snapout cotter key remover
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Installs, holds, or removes cotter keys and retaining pins from line hardware using a hot stick.
Max:
Min: 1
Step: 1
SYS-TEC-TM01100301-01
Snatch block, patesca-type, with forged steel hook
Load Handling Equipment

To be designed as per IEC, ASTM codes

Redirects a pulling line and supports controlled lifting or pulling of loads during electrical network work.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120147-01
Spiral disconnect
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Engages and disconnects suitable line fittings or hardware using a spiral hot-stick attachment.
Max:
Min: 1
Step: 1
SYS-TEC-TM03130101-01
Spiral link stick
Conductor Support Equipment

Rod Ø 32 mm (1-1/4 in); insulating length 960 mm (37.8 in).

Provides an insulated mechanical link for supporting or transferring conductor tension.
Max:
Min: 1
Step: 1
SYS-TEC-TM03270101-01
Static ground set
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Dissipates or equalizes static charge on conductors and support equipment during maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03120101-01
Strain link stick
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Provides an insulated mechanical link for supporting or transferring conductor tension.
Max:
Min: 1
Step: 1
SYS-TEC-TM03170201-01
Strain pole
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Transfers or supports conductor strain while maintaining electrical insulation during line maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM06040301-01
Swivel hook ladder
Insulated Scaffold and Ladders

To be designed as per IEC, ASTM codes

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM01030103-01
Swivel Transformer Gin
Load Handling Equipment

To be designed as per IEC, ASTM codes

Acts as a temporary lifting mast for raising or positioning transformer-related loads and line equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM03200111-01
Take-up trunnion
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Supports take-up and tensioning arrangements used in temporary conductor support systems.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120176-01
Telecommunications network support hook
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Supports or positions telecommunications cables and associated network hardware.
Max:
Min: 1
Step: 1
SYS-TEC-TM12020201-01
Temporary grounding set for conventional secondary networks (LV), with 5 clamps
Temporary Grounding Equipment and Hot Sticks

Five clamp rods Ø 25 × 300 mm; maximum clamp connection Ø 19 mm; 25 mm² cable in four 400 mm lengths (total 1.60 m).

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12030103-01
Temporary grounding set for medium-voltage networks up to 36 kV, without hot stick
Temporary Grounding Equipment and Hot Sticks

25 mm² copper cable, total 16 m (2 × 2 m + 1 × 12 m); grounding auger Ø 17 × 1000 mm; three-section operating stick total length 3.96 m.

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12020301-01
Temporary grounding set for multiplex network (LV)
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12030101-01
Temporary grounding set for overhead distribution up to 36 kV (three-phase), with insulating hot sticks
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12030201-01
Temporary grounding set for overhead distribution up to 36 kV (three-phase), with telescoping hot stick
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12010201-01
Temporary grounding set for single-phase network, with single hot stick
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12010101-01
Temporary grounding set for single-phase network, with telescopic hot stick
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM12040305-01
Temporary grounding set for substation up to 138 kV
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Temporarily bonds and grounds de-energized conductors or equipment to control hazardous induced or accidental voltage.
Max:
Min: 1
Step: 1
SYS-TEC-TM05090101-01
Temporary jumper protection device
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Protects and controls a temporary jumper to reduce accidental contact, abrasion, or unsafe movement.
Max:
Min: 1
Step: 1
SYS-TEC-TM13020301-01
Tool bag for grounding set (LV), 5 clamps
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM13020101-01
Tool bag for rural grounding set (single-phase)
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM03060102-01
Tower type saddle
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Provides a mounting saddle for temporary conductor-support equipment on tower structures.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080105-01
Transformer bushing clamp with insulated grip, with connector
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080105-02
Transformer bushing clamp with insulated grip, with pin
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080101-01
Transformer bushing clamp, with connector and eyescrew
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080104-01
Transformer bushing clamp, with connector and T-type screw
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080102-01
Transformer bushing clamp, with pin and eyescrew
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM05080103-01
Transformer bushing clamp, with pin and T-type screw
Insulated Jumper Tools

To be designed as per IEC, ASTM codes

Connects a temporary jumper or grounding lead to a transformer bushing using the stated operating feature.
Max:
Min: 1
Step: 1
SYS-TEC-TM02140101-01
Tree trimmer
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Trims vegetation near overhead conductors while maintaining increased working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM01090107-01
Triple rope block
Load Handling Equipment

Width 115 mm (4-1/2 in); length 300 mm (11-3/4 in).

Provides mechanical advantage for lifting, lowering, or positioning tools and components using rope.
Max:
Min: 1
Step: 1
SYS-TEC-TM10040101-01
Trolley
Compact Networks

To be designed as per IEC, ASTM codes

Moves along a conductor or support path to assist installation and positioning in compact networks.
Max:
Min: 1
Step: 1
SYS-TEC-TM12030501-01
Truck grounding set
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Bonds a work vehicle or truck to earth to reduce hazardous touch potential.
Max:
Min: 1
Step: 1
SYS-TEC-TM06110101-01
Twin step ladder with fiberglass steps
Insulated Scaffold and Ladders

To be designed as per IEC, ASTM codes

Provides insulated access, working support, or structural components for elevated electrical maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120150-01
Universal adapter
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Connects a specialized attachment to a universal hot stick for remote electrical maintenance work.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120175-01
Universal adapter for steel sponge
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Connects a specialized attachment to a universal hot stick for remote electrical maintenance work.
Max:
Min: 1
Step: 1
SYS-TEC-TM02120177-01
Universal head
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Connects a specialized attachment to a universal hot stick for remote electrical maintenance work.
Max:
Min: 1
Step: 1
SYS-TEC-TM02100101-01
Universal pole
Insulated Hand Tools

To be designed as per IEC, ASTM codes

Accepts universal hot-stick attachments for remote operation of line hardware near energized conductors.
Max:
Min: 1
Step: 1
SYS-TEC-TM12090110-01
Unshrouded threaded aluminum ferrule
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Terminates a temporary grounding cable and provides a threaded connection to compatible grounding hardware.
Max:
Min: 1
Step: 1
SYS-TEC-TM12090210-01
Unshrouded threaded copper ferrule
Temporary Grounding Equipment and Hot Sticks

To be designed as per IEC, ASTM codes

Terminates a temporary grounding cable and provides a threaded connection to compatible grounding hardware.
Max:
Min: 1
Step: 1
SYS-TEC-TM11010101-01
Warning sphere 300 mm
Warning Spheres

Diameter 300 mm

Marks overhead conductors to improve visibility to aircraft and reduce collision risk.
Max:
Min: 1
Step: 1
SYS-TEC-TM11010201-01
Warning sphere 600 mm
Warning Spheres

Sphere diameter 600 mm (24 in).

Marks overhead conductors to improve visibility to aircraft and reduce collision risk.
Max:
Min: 1
Step: 1
SYS-TEC-TM13030101-01
Waterproof canvas helmet bag
Tool Bags

To be designed as per IEC, ASTM codes

Stores, protects, and transports the specified electrical maintenance tools or personal protective equipment.
Max:
Min: 1
Step: 1
SYS-TEC-TM01070101-01
White Braided Rope
Load Handling Equipment

To be designed as per IEC, ASTM codes

Used as a hand line, pulling line, or general-purpose rigging rope for electrical maintenance activities.
Max:
Min: 1
Step: 1
SYS-TEC-TM01150101-01
Winch hoist puller
Load Handling Equipment

Cable Ø 4.76 mm; single-line cable length 6000 mm; double-line cable length 3000 mm.

Provides controlled manual pulling, lifting, and tensioning for conductors, equipment, and rigging.
Max:
Min: 1
Step: 1
SYS-TEC-TM10020101-01
Wire handle
Compact Networks

To be designed as per IEC, ASTM codes

Pulls, guides, or positions conductor during compact-network installation and maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM14020101-01
Wire rope tensioning clamp
De-energized Networks Equipment

To be designed as per IEC, ASTM codes

Grips and tensions conductor, guy wire, or wire rope during line construction, sagging, or maintenance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03010101-01
Wire tong
Conductor Support Equipment

Rod Ø 38 mm (1-1/2 in); insulated length 1740 mm (5 ft 9 in); overall length 2160 mm (7 ft 1 in).

Supports, lifts, or repositions an energized conductor while maintaining an insulated working distance.
Max:
Min: 1
Step: 1
SYS-TEC-TM03070206-01
Wire tong pole clevis
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Connects a wire tong to a support or saddle assembly.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050105-01
Wire tong saddle
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Mounts and supports a wire tong on a pole or temporary support assembly.
Max:
Min: 1
Step: 1
SYS-TEC-TM03050201-01
Wire tong saddle extension
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Extends the mounting position of a wire-tong saddle for temporary conductor support.
Max:
Min: 1
Step: 1
SYS-TEC-TM03070205-01
Wire tong stirrup
Conductor Support Equipment

To be designed as per IEC, ASTM codes

Provides a support connection point for a wire tong during conductor handling.
Max:
Min: 1
Step: 1
REGISTER NOW